For most Perth metropolitan properties, BAL is not a controlling factor in the glazing decision. For properties in or near bushfire-prone areas, particularly in the Perth Hills, parts of Wanneroo, coastal suburbs near bushland reserves, and rural and semi-rural WA, the BAL rating dictates what glazing systems are permitted under the National Construction Code.

This guide explains what BAL-40 and BAL-FZ require, how they differ from the more common BAL-29 (which Penot Double Glazing supplies), what the building permit process involves for high-BAL properties, and how to find specialist suppliers for BAL-40 and above. Drawn from AS 3959:2018, NCC 2022 Volume 2, DFES bushfire-prone area mapping, and the Fire Protection Association Australia BPAD accreditation framework.

Important scope note: Penot Double Glazing supplies double glazing compliant up to BAL-29. This guide covers BAL-40 and BAL-FZ requirements so homeowners in higher-rated areas understand what they need and who to approach. For BAL-40 and BAL-FZ projects, specialist bushfire glazing suppliers are required.

How BAL-40 and BAL-FZ Differ from BAL-29

AS 3959:2018 (Construction of Buildings in Bushfire-Prone Areas) defines six Bushfire Attack Level (BAL) ratings based on radiation heat flux at the building during a design bushfire event.

BAL RatingRadiation Heat Flux (kW/m²)Flame Contact Risk
BAL-LOWLess than 12.5None
BAL-12.5Up to 12.5Minimal
BAL-1912.5 to 19Increasing ember attack
BAL-2919 to 29Increasing ember attack and radiant heat
BAL-4029 to 40Increasing risk of flame contact
BAL-FZGreater than 40Direct flame contact

The jump from BAL-29 to BAL-40 is significant. BAL-29 properties face increasing radiant heat and ember risk but not direct flame contact. BAL-40 properties face possible flame contact. BAL-FZ (Flame Zone) properties face direct flame exposure during a design bushfire event.

Glazing requirements escalate accordingly. The construction standards are not interchangeable: a BAL-29 window is not compliant on a BAL-40 property regardless of how the supplier might describe it.

What AS 3959:2018 Specifies for BAL-40 Glazing

Three Deemed-to-Satisfy compliance paths under AS 3959:2018 Clause 8.5 for BAL-40 glazing:

Path 1: Toughened glazing with bushfire shutter. Toughened glass minimum 6mm thickness in metal frames, with a compliant bushfire shutter that provides protection during a bushfire event. The shutter must be operable from inside and rated to AS 3959 requirements.

Path 2: Toughened glazing with metal screen. Toughened glass minimum 6mm in metal frames, with an external glazing protection screen in corrosion-resistant steel or bronze mesh. Aluminium mesh is not permitted. The screen must be fixed and permanent.

Path 3: Tested assembly. A complete glazing assembly (glass plus frame plus seals) tested to AS 1530.8.1 as a tested system. The required FRL is confirmed in the tested assembly’s documentation and by the building surveyor. This is a complete tested system, not components specified individually.

For all three paths, framing must be metal (aluminium or steel), and the glazing assembly must be installed per the manufacturer’s specifications including any required corner detailing and head flashing.

What BAL-FZ Requires Beyond BAL-40

BAL-FZ glazing is fundamentally different. No simple Deemed-to-Satisfy path exists. The compliance path under AS 3959 / NCC Clause 9.5 is:

  • Tested assembly to AS 1530.8.2 with Fire Resistance Level of integrity, insulation and radiation of 30/30/30 minimum. Some applications require an FRL of 60/60/60.
  • Non-combustible framing typically required, with sealed perimeter assembly to the surrounding wall
  • Compliant bushfire shutter as an alternative path in some applications, with shutter rated to AS 3959 requirements
  • No exposed combustible elements within the glazing assembly

The product range available for BAL-FZ compliance is narrow. Suppliers offering certified BAL-FZ glazing typically work with specific tested assemblies using specialist fire-rated glazing systems from certified manufacturers. These are commercial-grade products with commercial-grade pricing.

Which Glass Types Satisfy Each BAL Rating

Glass TypeBAL-LOW to 12.5BAL-19BAL-29BAL-40BAL-FZ
Annealed (standard) glassOKNot OKNot OKNot OKNot OK
Toughened (6mm)OKOKOKWith screen/shutterNot OK
LaminatedOKOKOKWith screen/shutterNot OK
Tested fire-rated assemblyOKOKOKOKOK (assembly-specific)
Glass blocksLimited applicationNot OKNot OKNot OKNot OK

Standard double glazed IGUs with toughened glass meet BAL-29 requirements when supplied in compliant metal frames. For BAL-40, the addition of a tested screen or shutter is required. For BAL-FZ, a complete tested assembly is required.

Some premium residential lift-and-slide systems have documented AS 3959 compliance up to BAL-40 when specified with appropriate screen protection; confirm with the manufacturer and your building surveyor.

How to Confirm Your Property’s BAL Rating

The process:

Step 1: Check the DFES Bush Fire Prone Area map. The official map covers all of Western Australia. The 2023 V7.0 update introduced two categories (BPA 1 and BPA 2). Properties inside the BPA designation require a BAL assessment for new building or substantial renovation.

Step 2: Engage an FPAA BPAD-accredited assessor. The Fire Protection Association Australia maintains the BPAD register of accredited assessors. The assessor visits the property, measures the slope, vegetation type, vegetation distance, and applies the AS 3959 methodology to produce a BAL rating for the building envelope. The rating is the legal basis for building approval.

Step 3: Specify glazing per the BAL rating. Once the BAL rating is confirmed, the glazing specification follows. For BAL-29 and below, mainstream double glazing suppliers including Penot Double Glazing meet the requirement. For BAL-40 and BAL-FZ, specialist suppliers are required.

Step 4: Building permit and certification. The building surveyor confirms that the proposed glazing meets the AS 3959 requirements for the property’s BAL rating. The certifier reviews installation against the manufacturer’s specifications.

The Building Permit Process for BAL-40 and BAL-FZ Properties in WA

For a new build or substantial renovation on a BAL-40 or BAL-FZ property, the building permit process includes specific bushfire-related steps:

  • BAL assessment by an accredited BPAD assessor (typical cost $300 to $800 in 2026)
  • Building envelope design that meets AS 3959 for the assessed BAL level
  • Glazing system specification from a supplier with documented compliance
  • Manufacturer’s installation certificate confirming the assembly was installed per the tested specification
  • Building surveyor certification confirming compliance

The total project cost premium over equivalent non-BAL construction can be 10 to 25 per cent for BAL-40 and 25 to 50 per cent for BAL-FZ, depending on the building envelope and finishes specified.

How Penot Double Glazing Supplies Bushfire-Rated Glazing in WA

Penot Double Glazing supplies double glazing compliant up to BAL-29 specification. The product range covers toughened glass IGUs in metal frames with the AS 2047 and AS 1288 compliance required by the NCC at this BAL level.

For BAL-29 projects, the Penot Double Glazing BAL-29 page covers the product detail. Common BAL-29 projects in WA include Perth Hills properties, semi-rural Wanneroo, and coastal properties adjacent to bushland reserves. The windows range covers the toughened double glazed configurations that meet BAL-29.

For BAL-40 and BAL-FZ projects, Penot Double Glazing does not supply. These projects require specialist bushfire glazing systems from suppliers offering tested assemblies to AS 1530.8.1 (BAL-40) or AS 1530.8.2 (BAL-FZ). The building surveyor and BAL assessor confirm the specialist supplier specification during the building permit process.

This is an honest scope limit. The right specialist supplier for BAL-40 or BAL-FZ varies by project; the BAL assessor or building surveyor can recommend approved options.

Questions to Ask Your Builder or Certifier Before Ordering Windows for a High-BAL Property

  • What is the certified BAL rating for the property and when was it assessed?
  • Has the BAL assessment been formally lodged with the local council and the building surveyor?
  • For BAL-40, which compliance path are we using: shutter, screen, or tested assembly?
  • For BAL-FZ, which tested assembly is specified and from which supplier?
  • Who certifies the install: the supplier, the builder, the building surveyor?
  • What documentation is provided at handover for the bushfire compliance file?
  • What ongoing maintenance is required on the glazing assembly to maintain compliance?

A builder unable to answer all of these has not done the BAL compliance work properly. The BAL rating is not a checkbox; it is the basis of the building permit, the insurance, and the property’s safety in a bushfire event.

Where Penot Double Glazing Fits

Penot Double Glazing is a full AGWA member based at 92 Beechboro Rd S, Bayswater WA 6053, supplying double glazing up to BAL-29 compliance. For Perth Hills, coastal and semi-rural WA properties with BAL-29 rating, the BAL-29 product range covers the requirement. For BAL-40 and BAL-FZ properties, specialist suppliers are required; the building surveyor and BAL assessor confirm options during the building permit process.

For a quote on a BAL-29 property, book a free in-home assessment. Compare options across the double glazing services Perth range, call 1300 121 603, or visit the Bayswater showroom at 92 Beechboro Rd S. Our choosing a double glazing company guide covers what to ask any supplier, including for BAL-rated projects.

For homeowners in the western suburbs near coastal bushland reserves, our Perth western suburbs guide covers the BAL question for that area. The 30 questions answered guide covers the related compliance and warranty questions.

What’s the Difference Between BAL-29, BAL-40 and BAL-FZ Glazing?

BAL-29 covers properties exposed to radiation heat flux below 29 kW/m² with no direct flame contact. BAL-40 covers exposure up to 40 kW/m² with potential for flame contact. BAL-FZ (Flame Zone) covers direct flame contact above 40 kW/m². Glazing requirements escalate sharply: BAL-29 allows toughened glass with metal screens; BAL-40 requires testing or compliant screens; BAL-FZ requires assemblies tested to AS 1530.8.2 with 30-minute fire resistance level. Some applications require an FRL of 60/60/60.

Who Installs BAL-40 and BAL-FZ Glazing in Perth?

BAL-40 and BAL-FZ glazing systems are specialist products requiring assemblies tested under AS 1530.8.2 for fire resistance. Penot Double Glazing supplies up to BAL-29 specification only. For BAL-40 and BAL-FZ projects, specialist bushfire glazing suppliers are required, and the building surveyor and BAL assessor confirm the assembly specifications during the building permit process.

How Do I Find Out if My Perth Property Is in a Bushfire-Prone Area?

The DFES Map of Bush Fire Prone Areas (BPA) is the official source. The 2023 V7.0 update covers all of Western Australia with two categories: BPA 1 and BPA 2. The map is available at dfes.wa.gov.au/hazard-information/bushfire/bushfire-prone-areas. A BAL assessment by an accredited FPAA BPAD assessor produces the specific BAL rating for the property’s building envelope.

Does BAL-40 or BAL-FZ Affect Property Values in Perth?

BAL ratings primarily affect building cost and ongoing maintenance, not directly the value. A BAL-40 or BAL-FZ rated property requires more expensive bushfire-rated building elements (windows, doors, decking, gutters), which adds to new build and major renovation cost. The buyer expectation is that these elements are installed correctly, certified, and maintained. The BAL rating is disclosed in the contract of sale.